Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Revision 15
Serial Interface Operation 5–37 MN-LPOD
Parameter
Type
(* indicates
End-of-Life)
Instruction Code and
Arguments
for Command
or Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
(see Description of
Command Query
Response to
Command
Response
to Query
numeric
Sets or returns switching of the bias tee into the through state or into the off state,
in the form x, where:
0=Off State (mute LNB) (DEFAULT)
1=Through State (unmute LNB)
NOTES:
1) The bias tee provides a means of muting the LNB. The SBT state will be
controlled by the amplifier mute state while running in redundancy mode,
but while the unit is not in redundancy mode the bias tee may be set
independently of the amplifier mute state.
2) To send this command the unit must have the bias tee option installed;
otherwise, a mode error will result. A mode error will also result if this
command is sent while the unit is running in redundancy mode.
COMMAND EXAMPLE: <0001/SBT=1{CR}
SBT?
SBT*
Address
numeric
Sets or returns the FSK Address in the form xx, where:
xx=Address value from 01 (DEFAULT) to 15.
COMMAND EXAMPLE: <0001/SFA=01{CR}
SFA?
SFA*
Status*
Returns the summary fault state in the form x, where:
0=Not Faulted (SumFLT_COM J6 pin K is not connected to SumFLT_NC J6 pin
M)
1=Faulted (SumFLT_COM J6 pin K is connected to SumFLT_NC J6 pin M)
EXAMPLE: <0001/SFS?{CR}
Authentication
Trap Enable
Sets or returns the SNMP Authentication Trap in the form x, where:
0=Disabled
1=Enabled
COMMAND EXAMPLE: <0001/SNA=0{CR}
SNA?