Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Revision 15
Serial Interface Operation 5–38 MN-LPOD
Parameter
Type
(* indicates
End-of-Life)
Controller-to-Target
Instruction Code and
Qualifier
Arguments
for Command
or Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
Target-to-Controller
(see Description of
Arguments)
Command Query
Response to
Command
Response
to Query
SNMP Enable
SNM=
SNM?
1 byte
Command or Query.
Sets or returns SNMP in the form x, where:
0=Disabled
1=Enabled
COMMAND EXAMPLE: <0001/SNM=0{CR}
SNM=
SNM?
SNM=x
Serial Number
N/A
SNO?
9 bytes
Query only.
Returns the unit’s nine-digit serial number in the form xxxxxxxxx.
NOTE: This query is functionally identical to RSN.
EXAMPLE: <0001/SNO?{CR}
>0001/SNO=012345678{CR}{LF}
SNO=
SNO=xxxxx
xxxx
Set Physical
remote Address
SPA=
SPA?
4 bytes
Command or Query.
Sets or returns the Physical Address in the form xxxx where:
xxxx=Address value from 0001 (DEFAULT) to 9999.
COMMAND EXAMPLE: <0001/SPA=0412{CR}
SPA=
SPA?
SPA*
SPA=xxxx
SNMP Read
Community
SRC=
SRC?
16 bytes,
characters, no
spaces
Command or Query.
Sets or returns the SNMP Read Community string.
NOTE: An empty string is not allowed.
COMMAND EXAMPLE: <0001/SRC=public{CR}
SRC =
SRC!
SRC=x
SNMP System
Contact
SSC=
SSC?
255 bytes,
characters
Command or Query.
Sets or returns the SNMP System Contact string.
COMMAND EXAMPLE: <0001/SSC=Joe Net Admin{CR}
NOTE: When not configured, the target returns an empty string:
<0001/SSC={CR}{LF}
SSC =
SSC!
SSC=x
[1..128]
Set Statistics
Interval
SSI=
SSI?
2 bytes
Command or Query.
Sets or returns the time interval, in minutes, at which statistics are logged in the
form xx, where:
xx=interval, from 01 to 99 minutes (SEE NOTE)
Default value: 90 minutes.
COMMAND EXAMPLE: <0001/SSI=90{CR}
SSI=
SSI?
SSI=xx