- 110 -
-
-
-
The waveform and corresponding scale appears in the IBP Waveform Area with 3 dotted lines
representing High Limit Scale, Reference Scale, and Low Limit Scale from the top to the bottom. Values
of the three scales can be user-set according to the instruction given below.
IBP label: selectable from ART, PA,
CVP, RAP, LAP,
ICP
, P1, P2 ;
HI: IBP value of High Limit scale, the range is the measuring range of the current pressure
Note
Note
Note
Note
The
The
The
The HI
HI
HI
HI value
value
value
value must
must
must
must be
be
be
be higher
higher
higher
higher than
than
than
than the
the
the
the LO
LO
LO
LO value.
value.
value.
value.
LO: IBP value of Low Limit scale, the range is the measuring range of the current pressure.
Note
Note
Note
Note
The
The
The
The LO
LO
LO
LO value
value
value
value must
must
must
must be
be
be
be lower
lower
lower
lower than
than
than
than the
the
the
the HI
HI
HI
HI value
value
value
value .
.
.
.
VAL: IBP value of Reference scale (between HI and LO) .
.
.
.
.
Note
Note
Note
Note
When
When
When
When change
change
change
change HI
HI
HI
HI scale,
scale,
scale,
scale, Low
Low
Low
Low scale
scale
scale
scale or
or
or
or Reference
Reference
Reference
Reference scale
scale
scale
scale of
of
of
of IBP
IBP
IBP
IBP waveform
waveform
waveform
waveform and
and
and
and the
the
the
the corresponding
corresponding
corresponding
corresponding
IBP
IBP
IBP
IBP waveforms
waveforms
waveforms
waveforms are
are
are
are displayed
displayed
displayed
displayed under
under
under
under the
the
the
the menu
menu
menu
menu window,
window,
window,
window, the
the
the
the waveform
waveform
waveform
waveform will
will
will
will come
come
come
come penetratingly
penetratingly
penetratingly
penetratingly
through
through
through
through the
the
the
the menu
menu
menu
menu window
window
window
window for
for
for
for observing.
observing.
observing.
observing.
15.5
15.5
15.5
15.5 Alarm
Alarm
Alarm
Alarm Information
Information
Information
Information and
and
and
and Prompts
Prompts
Prompts
Prompts
Alarm
Alarm
Alarm
Alarm Messages
Messages
Messages
Messages
Among physiological alarms, those belonging to the type that the parameter has exceeded the limits
may activate the recorder to automatically output the parameters and related measured waveforms
when the alarms occur on the condition that the alarm record switch in the related menu is On.
Tables below describe the possible physiological alarms, technical alarms and prompt messages
occurring during IBP measurement.
Physiological alarms:
Message Cause Alarm Level
IS1 TOO HIGH
SYS measuring value of channel 1 is
above upper alarm limit.
User-selectable
IS1 TOO LOW
SYS measuring value of channel 1 is
below lower alarm limit.
User-selectable
ID1 TOO HIGH
DIA measuring value of channel 1 is
above upper alarm limit.
User-selectable
ID1 TOO LOW
DIA measuring value of channel 1 is
below lower alarm limit.
User-selectable
IM1 TOO HIGH
M AP measuring value of channel 1 is
above upper alarm limit.
User-selectable
IM1 TOO LOW
M AP measuring value of channel 1 is
below lower alarm limit.
User-selectable
IS2 TOO HIGH
SYS measuring value of channel 2 is
above upper alarm limit.
User-selectable

Other manuals for Contec CMS8000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Contec CMS8000 and is the answer not in the manual?

Contec CMS8000 Specifications

General IconGeneral
CategoryMedical Equipment
Device NameContec CMS8000
TypePatient Monitor
ECG Lead Mode3-lead or 5-lead
Resolution800 x 600
Power SupplyAC 100-240V, 50/60Hz
BatteryRechargeable lithium battery
Operating Temperature5°C to 40°C
Storage Temperature-20°C to 55°C
DisplayTFT LCD
Screen Size12.1 inches
ParametersECG, RESP, NIBP, SpO2, TEMP, PR
InterfaceEthernet, Nurse call
Humidity15% to 95% non-condensing
Battery LifeApproximately 4 hours