Menu 12
Parameter
structure
Keypad and
display
Parameter x.00
Parameter description
format
Advanced parameter
descriptions
Serial comms
protocol
Performance
166 Mentor MP Advanced User Guide
www.controltechniques.com Issue Number: 4
Old value of
Pr 12.41
New value of
Pr 12.41
Pr 8.12 Pr 8.22 Pr 8.32 Pr 8.17 Pr 8.27
Drive OK output Brake release output
Any 1 0 Pr 10.01 10Pr 12.40
Brake release output
Not 1 2 0 Pr 12.40 1 No change No change
Brake release output Drive OK output
120Pr 12.40 10Pr 10.01
Not stop Drive OK output
10 or 30Pr 6.39 00Pr 10.01
Reset
20 or 30Pr 10.33 0 No change No change