Curtis 1298 Manual, OS 11
65
4a — MONITOR MENU
Interlock On/Off Interlock input on or off. The source of the
Interlock_State On/Off interlock input is determined by the Interlock
System_Flags1 [Bit 0] Type parameter:
from Switch 3 (pin 9) if Interlock Type = 0
from VCL function if Interlock Type = 1
from KSI (pin 1) if Interlock Type = 2.
Emer Rev On/Off Emergency reverse input on or off. The
EMR_State On/Off source of the emergency reverse input is
System_Flags1 [Bit 1] determined by the EMR Type parameter:
from Switch 1 (pin 24) if EMR Type = 0
from VCL function if EMR Type = 1.
Analog 1 0–10.0 V Voltage at analog 1 (pin 24).
Analog1_Input 0–1023
Analog 2 0–10.0 V Voltage at analog 2 (pin 8).
Analog2_Input 0–1023
Switch 1 On/Off Switch 1 on or off (pin 24).
Sw_1 On/Off
Switches [Bit 0]
Switch 2 On/Off Switch 2 on or off (pin 8).
Sw_2 On/Off
Switches [Bit 1]
Switch 3 On/Off Switch 3 on or off (pin 9).
Sw_3 On/Off
Switches [Bit 2]
Switch 4 On/Off Switch 4 on or off (pin 10).
Sw_4 On/Off
Switches [Bit 3]
Switch 5 On/Off Switch 5 on or off (pin 11).
Sw_5 On/Off
Switches [Bit 4]
Switch 6 On/Off Switch 6 on or off (pin 12).
Sw_6 On/Off
Switches [Bit 5]
Switch 7 On/Off Switch 7 on or off (pin 22).
Sw_7 On/Off
Switches [Bit 6]
Switch 8 On/Off Switch 8 on or off (pin 33).
Sw_8 On/Off
Switches [Bit 7]
Monitor Menu: INPUTS,
cont’d
DISPLAY
VARIABLE RANGE DESCRIPTION