6.4 Printer parameters
The parameters marked with the symbol
D
are the default values.
Settings remain active even after the device has been turned off and they are stored in non-volatile memory.
PRINTER EMULATION Available emulations for the device:
CUSTOM/POS
SVELTA
D
RS232 BAUD RATE Communication speed of the serial interface:
1200 2400
4800 9600
19200 38400
57600 115200
D
NOTE: Parameter valid only with serial interface.
RS232 DATA LENGTH Number of bit used for characters encoding:
8 bits/car
D
7 bits/car
NOTE: Parameter valid only with serial interface.
RS232 PARITY Bit for the parity control of the serial interface:
None
D
= parity bit omitted
Even = even value for parity bit
Odd = odd value for parity bit
NOTE: Parameter valid only with serial interface.
RS232 HANDSHAKING Handshaking:
XON/XOFF
D
= software handshaking
Hardware = hardware handshaking (CTS/RTS)
NOTE: Parameter valid only with serial interface.
BUSY CONDITION Activation mode for the Busy signal:
RXFull
D
= Busy signal is activated when the buffer is full
OffLine/ RXFull = Busy signal is activated when the device is both in OffLine status and
the buffer is full
NOTE: Parameter valid only with serial interface.
91