CVC TECHNOLOGIES, INC. CVC 310 OPERATION MANUAL
8.2 LCD Display Descriptions
LCD-1
8 - 3
F1 AUTO ADJ
F2 CALL
F3 CURRENT MEM
F1: Select this key for new products, new bottles (container) or new labels.
F2: Call job setting from memory for reuse (job #1 through #50)
F3: Continue with the same job as before the last power off.
LCD-2
F1 OUTPUT
F2 REMNING
F3 PD SPD
F1: Output in total
F2: Label remaining quality
F3: Labeling speed
LCD-3
F1 LAB SPD
F2 EXTNSN
F3 POSITN
F1: Label dispense speed
F2: Label extension beyond the label peel blade edge.
F3: Label placement position.
LCD-4
F2 SENSITVY
F3 LAB SENS
F2: transmittance value of backing paper detected by SelfSet
TM
F3: Setting value for label sensitivity.