CVC TECHNOLOGIES, INC. CVC 310 OPERATION MANUAL
Press to enter the bottle diameter and then press key to confirm.
Press to enter the label length, and then press key to confirm.
Finally save the labeling data in memory: Press key → Job number → and then key
to confirm.
Note: (Refer to chapter 8.3)
*If the machine speed and other settings are satisfactory, the operator can save the job setup into any
of the 50 available memory positions numbered #1~#50.
* To change the machine speed or other settings, press (PD SPD) key or key, and then
move to the desired display to make the change.
d. To recall memory from a previously saved job settings for reuse:
There are two ways to call a previous job setting:
1) Press key → memory number → key, finally press key to start the conveyor.
2) Press key → memory number → key, finally press key to start the conveyor.
e. To continue working with the same labeling job before the last power-off, after starting the machine,
press key, and then key to confirm, finally press key to start the conveyor.
10 - 4