ANNEX G: SUNDRIES PAGE 53
ANNEX G: MAINTENANCE AND MISCELANEOUS
THE INITIALIZATION PAGE
This page appears if a calculation is impossible, due to unprogrammed data
or an incorrect value.
It can also appear as a result of pollution of one of the memory zones which
will also give impossible calculations.
INITIALIZATION DNC 60 PS
-- MEMORY ZONE --
_ Clear variables zone
_ Clear punches-dies zone
_ Clear machine parameters zone
EXECUTION CODE ___
It can be necessary to display this page intentionally in order to clear com-
pletely the data of the DNC and to re-start the programming on a "clean" ba-
sis.
To display the initialization page:
Switch on the machine by pressing the
and keys.
In case of unexpected apparition of the init page, proceed as follows:
If point n° 1 does not re-establish a normal situation, go on to the next point
and so on.
The following operations clear successively all the data in the selected
memories.
It is therefore recommended to re-introduce the data.
1) Press the
key twice.
2) Enter:
value
1 in the field Clear variables zone
and value
817 in the field EXECUTION CODE.
Press the
key.
Press the
key twice.