EasyManuals Logo

CYBELEC DNC 60 PS User Manual

CYBELEC DNC 60 PS
113 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #63 background imageLoading...
Page #63 background image
ANNEX G: SUNDRIES PAGE 53
ANNEX G: MAINTENANCE AND MISCELANEOUS
THE INITIALIZATION PAGE
This page appears if a calculation is impossible, due to unprogrammed data
or an incorrect value.
It can also appear as a result of pollution of one of the memory zones which
will also give impossible calculations.
INITIALIZATION DNC 60 PS
-- MEMORY ZONE --
_ Clear variables zone
_ Clear punches-dies zone
_ Clear machine parameters zone
EXECUTION CODE ___
It can be necessary to display this page intentionally in order to clear com-
pletely the data of the DNC and to re-start the programming on a "clean" ba-
sis.
To display the initialization page:
Switch on the machine by pressing the
and keys.
In case of unexpected apparition of the init page, proceed as follows:
If point n° 1 does not re-establish a normal situation, go on to the next point
and so on.
The following operations clear successively all the data in the selected
memories.
It is therefore recommended to re-introduce the data.
1) Press the
key twice.
2) Enter:
value
1 in the field Clear variables zone
and value
817 in the field EXECUTION CODE.
Press the
key.
Press the
key twice.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CYBELEC DNC 60 PS and is the answer not in the manual?

CYBELEC DNC 60 PS Specifications

General IconGeneral
BrandCYBELEC
ModelDNC 60 PS
CategoryControl Systems
LanguageEnglish

Related product manuals