PAGE 56 USER GUIDE DNC 60 PS
THE INITIALIZATION PAGE
This page appears if a calculation is impossible, due to unprogrammed data
or an incorrect value.
It can also appear as a result of pollution of one of the memory zones which
will also result in impossible calculations.
INITIALIZATION DNC 60 G
---------
--MEMORY ZONE--
_ Clear variables zone
_ Clear machine parameters zone
_ Clear transmission RS232 zone
EXECUTION CODE ___
It may be necessary to use this page intentionally in order completely clear
the data on the DNC and to re-start the programming on a "clean" basis.
To display the Initialization page, press the
and keys.
If the Initialization page appears unexpectedly, proceed as follows:
Note: If point 1 does not re-establish a normal situation, go on to the next
point and so on. The following operations clear successively all the data in
the selected memories. It is therefore recommended to re-introduce the data.
5) Press the
key twice.
6) Enter:
- value
1 in the Clear variables zone field
- value
817 in the EXECUTION CODE.field
Press the
key.
Press the
key twice.