ANNEX G: SUNDRIES PAGE 57
7) Enter:
- value
1 in the Clear variables zone field,
- value
1 in the Clear machine parameters zone field
- value
817 in the EXECUTION CODE field.
Press the
key.
Press the
key twice.
8) Enter:
value
1 in the field Clear variables zone,
value
1 in the field Clear machine parameters zone,
value
1 in the field Clear transmission RS232 zone
and value
817 in the field EXECUTION CODE.
Press the
key.
Press the
key twice.
Clearing the machine parameters also deletes all the input / output configura-
tion defined by the operator.
We therefore recommend that the DNC 60 be re-configured before next use.
Important: If you use an external system for re-entering data (CYBACK
via RS232) and the problem persists, then the information re-entered by this
system have to checked again.
The best thing to do in this case is to again delete the whole contents of the
DNC and to re-program the DNC manually via the keyboard (not the RS232
line).
BEFORE CALLING FOR TECHNICAL HELP
Please have ready the following information:
Type of numerical control.
Serial Nr of the DNC.
DNC and axes (N2X) software numbers.
Name of the machine tool's manufacturer.
List of machine parameters (have on hand when the technician
comes).
The state of the numerical control:
- which LEDs are on?
- which message is on the screen ?
Details of what caused or is causing the problem.