Default Severity WARNING
Log Message Voltage monitor <index> (<name>) is outside the specified limit.
Current value is <current_voltage> <unit>, lower limit is
<min_limit>, upper limit is <max_limit>
Explanation The powersupply of this unit may be failing.
Gateway Action none
Recommended Action Change powersupply unit.
Revision 1
Parameters index
name
unit
current_voltage
min_limit
max_limit
2.23.4. voltage_normal (ID: 04000022)
Default Severity WARNING
Log Message Voltage monitor <index> (<name>) is outside the specified limit.
Current value is <current_voltage> <unit>, lower limit is
<min_limit>, upper limit is <max_limit>
Explanation The sensor reports that the voltage value is back in the normal
range.
Gateway Action None
Recommended Action None.
Revision 1
Parameters index
name
unit
current_voltage
min_limit
max_limit
2.23.5. fanrpm_alarm (ID: 04000031)
Default Severity WARNING
Log Message Fan RPM monitor <index> (<name>) is outside the specified limit.
Current value is <current_fanrpm> <unit>, value is
<current_fanrpm> <unit>, lower limit is <min_limit>, upper limit is
<max_limit>
Explanation The fan is behaving strange, this may because it is failing or blocked.