2.64.7. no_response_trying_to_create_rule (ID: 03800007)
Default Severity CRITICAL
Log Message No response from switch <switch> while trying to create <type>
rule in profile <profile>.
Explanation Several attempts to create a rule in the switch has timed out. No
more attempts will be made.
Gateway Action no_rule
Recommended Action Verify that the firewall is able to communicate with the switch.
Revision 1
Parameters type
profile
switch
2.64.8. failed_writing_zonededense_state_to_media (ID:
03800008)
Default Severity CRITICAL
Log Message Failed to write ZoneDefense state to media.
Explanation Failed to write list of ZoneDefense state to media. The media might
be corrupt.
Gateway Action None
Recommended Action Verify that the media is intact.
Revision 1
2.64.9. failed_to_create_access_rule (ID: 03800009)
Default Severity CRITICAL
Log Message Failed to create <ruletype> access rule to add <network> on
<switch>.
Explanation The switch returned an error while creating a rule.
Gateway Action None
Recommended Action Verify that the configured switch model is correct.
Revision 1
Parameters ruletype
network
switch