Recommended Action If the system is configured to use TCP based ALGs, increase the
amount of maximum sessions parameter on the associated service.
Revision 1
Parameters max_windows
[num_events]
2.57.19. tcp_get_freesocket_failed (ID: 03300024)
Default Severity WARNING
Log Message System was not able to get a free socket. Triggered <num_events>
times last 10 seconds.
Explanation The TCP stack could not get a free socket. This event was triggered
[num_events] times during the last 10 seconds.
Gateway Action None
Recommended Action None.
Revision 1
2.57.20. tcp_seqno_too_low_with_syn (ID: 03300025)
Default Severity DEBUG
Log Message TCP sequence number <seqno> is not in the acceptable range
<accstart>-<accend>. Dropping
Explanation A TCP segment with an unacceptable sequence number was
received. The packet will be dropped.
Gateway Action drop
Recommended Action None.
Revision 2
Parameters seqno
accstart
accend
Context Parameters Rule Name
Connection
Packet Buffer
Chapter 2: Log Message Reference