xStack® DES-3200 Series Layer 2 Ethernet Managed Switch CLI Reference Manual
32
9
show bpdu_tunnel
Used to sh
ow the BPDU Tunneling global state, tunnel destination MAC
address, and port state.
Purpose
sho
w bpdu_tunnel
Syntax
This
command is used to show the BPDU Tunneling global state, tunnel
destination MAC address, and port state.
Description
Non
e.
Parameters
Non
e.
Restrictions
Example usage:
To show the BPDU tunneling state of all ports:
DES-3200-28:4#show bpdu_tunnel
Command: show bpdu_tunnel
BPDU Tunnel : Enabled
STP Tunnel Multicast Address : 01:05:5D:00:00:00
STP Tunnel Port : 1,2
GVRP Tunnel Multicast Address : 01:05:5D:00:00:21
GVRP Tunnel Port :
Uplink Port :
DES-3200-28:4#
enable bpdu_tunnel
Used to ena
ble BPDU tunneling.
Purpose
enabl
e bpdu_tunnel
Syntax
This
command is used to enable the BPDU tunneling function. By
default, it is disabled.
Description
Non
e.
Parameters
Only Administrator-level users
can issue this command.
Restrictions
Example usage:
To enable BPDU tunneling:
DES-3200-28:4#enable bpdu_tunnel
Command: enable bpdu_tunnel
Success.
DES-3200-28:4#
disable bpdu_tunnel
Used to disab
le BPDU tunneling.
Purpose
disa
ble bpdu_tunnel
Syntax

Table of Contents