Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 1 - January 15, 2018
Rev. 2
Page 3.3.10
ITT
During engine start :
1 - Starting procedure Abort. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Refer to procedure Engine start, chapter 4.4
2 - Cancel the flight.
Inform maintenance department.
End of procedure ■
After engine start :
On ground :
3 - Cancel the flight.
Inform maintenance department.
End of procedure ■
In flight :
► Fly the airplane ◄
4 - T
RQ Reduce. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
To get ITT < 840°C
► Land as soon as possible ◄
Inform maintenance department.
End of procedure.