EasyManua.ls Logo

Daher TBM 930 - Pitot no Ht L-R

Daher TBM 930
877 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 1 - January 15, 2018
Rev. 3
Page 3.11.6
PITOT NO HT L-R
Indicates that :
- corresponding pitot tube heating has failed or
- PITOT L HTR switch or PITOT R & STALL HTR switch is not ON while the engine is
running.
If PITOT NO HT L :
Icing conditions may alter airspeed indications provided by ADC1.
1 - Avoid icing conditions.
Fly the airplane
If not possible :
2 - Perform moderate descent or climb attitudes.
V
MO
overshoot and stall warning system are always operating.
End of procedure
If PITOT NO HT R :
V
MO
overshoot warning may be altered by icing conditions.
Fly the airplane
3 - Airspeed Monitor below 266 KIAS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
End of procedure.