Pilot's Operating Handbook
Section 4
Normal procedures
EASA Approved
Edition 1 - January 15, 2018
Rev. 2
Page 4.4.33
After engine start with GPU
1 - SOURCE selector BATT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 - Electrical network Check. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 - GPU Disconnect. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Performed by ground personnel
4 - GPU DOOR Check OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5 - GENERATOR selector MAIN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 - MAIN GEN Check OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
● NOTE ●
MAIN GEN normally goes off as soon as STARTER goes off.
●
If MAIN GEN does not go off :
7 - Ng Increase over 70 %. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
To start main generator
8 - Generator and battery AMPS Check charge. . . . . . . . . . . . . . . . . . . . . . . . . . .
On EIS of MFD
9 - Battery and ESS. bus VOLTS Check voltage ≈ 28 Volts. . . . . . . . . . . . . . . .
On EIS of MFD
10 - CAS display Check. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11 - A/C switch As required. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12 - BLEED switch AUTO or MAX DIFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
When ground personnel is cleared from propeller area :
13 - Perform procedure After engine start. . . . . . . . . . . . . . . . . . . . . . . . . . .
Refer to procedure hereafter
End of procedure.