EasyManua.ls Logo

Daher TBM 930 - Fuel Low L-R

Daher TBM 930
877 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 1 - January 15, 2018
Rev. 0
Page 3.8.4
FUEL LOW L-R
Indicates a level drop in the corresponding tank.
1 - Corresponding gage Check. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 - Check the other tank has been automatically selected.
If other tank not automatically selected :
3 - FUEL SEL switch MAN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 - Select tank manually As required. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fly the airplane
5 - Minimum fuel Check. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 - Take decision.
If necessary :
Land as soon as practical
End of procedure.
PIM - DO NOT USE FOR FLIGHT OPERATIONS