Pilot's Operating Handbook
Section 4
Normal procedures
EASA Approved
Edition 1 - January 15, 2018
Rev. 5
Page 4.4.32
Motoring followed by an engine start 3/3
Continuing
Electric power
26 - MAIN GEN Check OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reset if necessary
NOTE
MAIN GEN normally goes off as soon as STARTER goes off.
If
MAIN GEN does not go off :
27 - Ng Increase to more than 70 %. . . . . . . . . . . . . . . . . . . . . . . . . . .
To start main generator
28 - Generator and battery AMPS Check charge. . . . . . . . . . . . . . . . . . . . .
On EIS of MFD
29 - Battery and ESS. bus VOLTS Check voltage 28 Volts. . . . . . . . . . .
On EIS of MFD
End of procedure.