Pilot's Operating Handbook
Section 4
Normal procedures
EASA Approved
Edition 1 - January 15, 2018
Rev. 5
Page 4.4.31
Motoring followed by an engine start 2/3
► Continuing
13 - Motor For 30 sec. max. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
After 20 seconds and if ITT < 150°C :
14 - IGNITION switch AUTO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
15 - Ng Check > 13 %. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16 - THROTTLE LO-IDLE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Monitor increase of :
17 - ITT max. : < 870°C for 20 sec max.. . . . . . . . . . . . . . . . . . . . . . .
< 1000°C for 5 sec max.
18 - Ng
19 - Oil pressure
20 -
OIL PRESS Check OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
When Ng > 50 % :
▲ CAUTION ▲
If the starter does not go off automatically, disengage it using the
ABORT position of the STARTER switch.
▲
21 - Starter Check OFF automatically. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
22 - STARTER Check OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
23 - Engine parameters Check. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Check 54 % ≤ Ng ≤ 58 %, oil pressure and ITT in green sector
Fuel panel
24 - AUX BP switch AUTO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
25 -
AUX BOOST PMP ON Check OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continue ►