Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 1 - January 15, 2018
Rev. 3
Page 3.10.12
DOOR
Indicates that one of the door latches of the door(s) is not correctly locked.
On ground :
1 - Check the correct locking, as well as the latches position of the door(s).
If DOOR is still ON :
2 - Do not take off.
End of procedure
In flight :
Fly the airplane
3 - S
tart a slow descent.
4 - Decrease cabin pressure differential By selecting a higher LFE. . . . .
(LFE between 9500 ft and 10000 ft)
If a real failure of one of the doors is noticed :
5 - Oxygen masks Use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 - BLEED switch OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7 - DUMP switch Actuate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
If necessary :
8 - Perform procedure Emergency descent. . . . . . . . . . . . . .
Refer to chapter 3.6
End of procedure.