EasyManua.ls Logo

Daher TBM 930 - Page 288

Daher TBM 930
877 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Pilot's Operating Handbook
Section 4
Normal procedures
EASA Approved
Edition 1 - January 15, 2018
Rev. 2
Page 4.4.26
Engine start 3/3
Continuing
When
- Ng > 50 % and,
- 1 minute max :
CAUTION
If the starter does not go off automatically, disengage it using the
ABORT position of the STARTER switch.
16 - Starter Check OFF automatically. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
17 - STARTER Check OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18 - Engine parameters Check. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Check 54 % Ng 58 %, oil pressure and ITT in green sector
End of procedure.
PIM - DO NOT USE FOR FLIGHT OPERATIONS

Table of Contents

Related product manuals