Pilot's Operating Handbook
Section 4
Normal procedures
EASA Approved
Edition 1 - January 15, 2018
Rev. 2
Page 4.4.26
Engine start 3/3
► Continuing
When
- Ng > 50 % and,
- 1 minute max :
▲ CAUTION ▲
If the starter does not go off automatically, disengage it using the
ABORT position of the STARTER switch.
▲
16 - Starter Check OFF automatically. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
17 - STARTER Check OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18 - Engine parameters Check. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Check 54 % ≤ Ng ≤ 58 %, oil pressure and ITT in green sector
End of procedure.