Enter/Exit Programming Mode
180
PowerScan™ PD9130/PBT9100/PM9100
Code 93 Set Length 2
This feature specifies one of the bar code lengths for Code 93 Length Con-
trol. Length 2 is the maximum label length if in Variable Length Mode, or the
second fixed length if in Fixed Length Mode. Length includes the bar code’s
check, data, and full-ASCII shift characte
rs. The length does not include
start/stop characters. The length can be set from 1 to 50 characters. A set-
ting of 0 specifies to ignore this length (only one fixed length).
Table 21 provides examples for setting Length 2. See page 298 for detailed
instructions on setting this feature.
Table 21. CODE 93 Length 2 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
00 (Ignore This
Length)
07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT CODE 93 LENGTH 2 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
Select Code 93 Length 2 Setting
To configure this feature, scan the ENTER/
EXIT bar code above, then the bar code at
left followed by digits from the Alphanu-
meric characters in Appendix D, Keypad
representing your desire
d character(s). End
by scanning the ENTER/EXIT bar code
again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
50 = Length 2 is 50 Characters