EasyManua.ls Logo

Datalogic PowerScan 9100 Series

Datalogic PowerScan 9100 Series
362 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Enter/Exit Programming Mode
70
PowerScan™ PD9130/PBT9100/PM9100
Good Read LED Duration
This feature specifies the amount of time that the Good Read LED remains
on following a good read. The good read LED on time can be set within a
range of 100 milliseconds to 25,500 milliseconds (0.1 to 25.5 seconds) in
100ms increments. A setting of 00 keeps the LED on until the next trigger
pull.
See page 307 in “References” for detailed instructions and examples for set-
ting this feature.
Good Read LED Duration Setting =
Keep LED on until next trigger pull
Select Good Read LED Duration Setting
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu-
meric characters in
Appendix D, Keypad
repre-
senting your desired character(s). End by scanning
the
ENTER/EXIT bar code twice.
Make a mistake? Scan the CANCEL
bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
DEFAULT
003 = Good Read LED
stays on for 300 ms.
Indicators are dimmed during sleep.

Table of Contents

Related product manuals