Enter/Exit Programming Mode
282
PowerScan™ PD9130/PBT9100/PM9100
Barcode/Key Different Data Format
If this parameter is enabled, barcode and keyboard entered data can be for-
matted separately. More specifically: if this parameter is disabled, barcode
and keyboard data will share the same Header
and Terminator defined using
“Set Barcode Header” and “Set Barcode Terminator” below. If this parameter
is enabled, keyboard entered data are treated differently, as their format
must be programmed through the parameters Set String Header, Set String
Terminator, Set Key Sequence Header and Set Key Sequence Terminator.
Disable
DEFAULT
Enable
Set Barcode Header
Sets the header for barcode and keyboard composed strings.
Set barcode header
To configure this feature, scan the ENTER/EXIT PROGRAM-
MING MODE bar code above, then the bar code at left fol-
lowed by 32 digits from the Alp
hanumeric characters in
Appendix D, Keypad
. The digits must be the hexadeci-
mal ASCII representation of the desired characters.
If less than the expected string of 16 characters are
se
lected, scan the ENTER/EXIT bar code to terminate the
string. If the first 2 digits are 0, the feature is disabled. End
by scanning the ENTER/EXIT bar code twice.