TC1200 REFERENCE MANUAL
114
5
5.1.2 RS232/USB COM Parameters
Intercharacter Delay
This parameter specifies the intercharacter delay between the end of one character and the
beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in
10 ms increments. A setting of zero specifies no delay.
To set the delay:
1. Determine the desired setting in milliseconds (x 10 ms). (0-99).
2. Use the Chart in Appendix C to find the hex equivalent for the desired numeric value.
3. Go to page 39 and scan the ENT
ER/EXIT PROGRAMMING MODE barcode to enter
Programming Mode.
4. Scan the barcode: SELECT INTERCHARACTER DELAY.
5. Scan the two hex equivalent characters from the keypad in Appendix B that represent the
numeric value determined in step 1 above.
NOTE
If you make a mistake before the last character, scan the CANCEL barcode
to abort and not save the entry string. You can then start again at the
beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit.
This completes the procedure.
Disable Character
Specifies the value of the RS232 host command used to disable the reader. Selections: a
character from NUL (0x00) to DEL (0x7F).
NOTE
The Enable Character must be different from the Disable Character and
must not contain reserved characters (see Appendix D). Settin
g to
previously defined characters such as XON, XOFF, or host commands
conflicts with normal operation of these characters. 8-bit data is not
recognized when the option Data Bits has been set as 7 Data Bits.
To set the value:
1. Determine the desired character. A setting of 0xFF indicates the Disable Character is not
used (not available).
2. Use the Chart in Appendix C to find the hex equivalent
for the desired character.
3. Go to page 39 and scan the ENT
ER/EXIT PROGRAMMING MODE barcode to enter
Programming Mode.
4. Scan the barcode: SELECT DEVICE DISABLE CHARACTER.
5. Scan the two hex equivalent characters
from the keypad in Appendix B that represent the
desired character in step 1 above.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.
This completes the procedure.