EasyManuals Logo

Datalogic TC1200 User Manual

Datalogic TC1200
160 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #42 background imageLoading...
Page #42 background image
TC1200 REFERENCE MANUAL
30
3
CODE SELECTION
Description Parameter Value
MSI
MSI Disable MSEN 00
Enable 01
Code Length Control Variable MSLC 00
Fixed 01
Set Length Length 1 (or Min Length) from 1 to 50 characters MSL1 v
Length 2 (or Max Length) 0 or from 1 to 50 characters MSL2 v
Check Options
Check Calculation Disable MSCC 00
Enable Mod 10 01
Enable Mod 11/10 02
Enable Mod 10/10 03
Check Tx Disable MSCT 00
Enable 01
Decoding Options
Minimum Reads One Read MSMR 01
Two Reads 02
Three Reads 03
Four Reads 04
Decoding Level Disable MSDL 00
Level 1 01
Level 2 02
Level 3 03
Level 4 04
Level 5 05
Stitching Disable MSST 00
Enable 01
v = Hex value from 00 to 32 representing the decimal number

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic TC1200 and is the answer not in the manual?

Datalogic TC1200 Specifications

General IconGeneral
BrandDatalogic
ModelTC1200
CategoryBarcode Reader
LanguageEnglish

Related product manuals