TC1200 REFERENCE MANUAL
30
3
CODE SELECTION
Description Parameter Value
MSI
MSI Disable MSEN 00
Enable 01
Code Length Control Variable MSLC 00
Fixed 01
Set Length Length 1 (or Min Length) from 1 to 50 characters MSL1 v
Length 2 (or Max Length) 0 or from 1 to 50 characters MSL2 v
Check Options
Check Calculation Disable MSCC 00
Enable Mod 10 01
Enable Mod 11/10 02
Enable Mod 10/10 03
Check Tx Disable MSCT 00
Enable 01
Decoding Options
Minimum Reads One Read MSMR 01
Two Reads 02
Three Reads 03
Four Reads 04
Decoding Level Disable MSDL 00
Level 1 01
Level 2 02
Level 3 03
Level 4 04
Level 5 05
Stitching Disable MSST 00
Enable 01
v = Hex value from 00 to 32 representing the decimal number