Chapter 8 Load Cell Module AS02LC
8- 7
8_
CR# Name Description
Att.
Default
36 mV/V
420 mV/V
540 mV/V
680 mV/V
61 Sampling cycle for CH2
02.5 ms
110 ms
216 ms
320 ms
450 ms
560 ms
6100 ms
7200 ms
8400 ms
R/W
4
62
Weight measured times in a
stability range for CH2
Range: K1K500
R/W
5
63
Stability range for CH2
Floating-point format
Range: 0–100000
R/W
10
64
65
Maximum weight for CH2
Floating-point format
Maximum measuring weight; when the
weight measured exceeds the limit, an
alarm is triggered. The value should be
greater than 1.
R/W
100,000
66
67 Filter mode for CH2
0: no filter (default)
1: maximum filter mode
2: average filter mode
R/W
0
68 Maximum filter for CH2
Range: 0–8; the bigger the number the
stronger the filter
R/W
1
69
Average weight measured
times for CH2
Range: 1–100
(for FW V1.04: 1–400 is available)
R/W
10
70
Upper limit of the zero return
for CH2
Floating-point format
Determines the current weight as the zero
point in the upper/lower range; when the
lower range is larger than the upper range,
R/W
10
71
72
Lower limit of the zero return
for CH2
R/W
-10
73

Table of Contents

Other manuals for Delta AS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta AS Series and is the answer not in the manual?

Delta AS Series Specifications

General IconGeneral
SeriesAS Series
Power Supply24VDC
Cooling MethodNatural convection
Programming LanguageFunction Block Diagram (FBD)
Communication InterfaceEthernet, RS-232, RS-485
Output Voltage24V DC
Output Current2A
Operating Temperature55°C
Storage Temperature70°C
Protection FeaturesOvervoltage
CertificationsCE, UL