Chapter 5 CANopen Operation Mode ASDA A2-E
5-14 Revision April, 2015
5.7 Profile Torque Mode
5.7.1 Description
The drive could receive torque command and plan profile torque slope.
5.7.2 Operation Procedures
1. Set Mode of operations:6060hto profile torque mode(4).
2. Set Controlword:6040has (0x6 0x7 0x0F) to Servo ON the drive and
enable the motor.
(After Servo On the drive, the internal torque command will be reset and OD-6071h
will be cleared. It means the drive is servo-on and starts to receive the torque
command.)
3. Set Torque slope:6087hto plan torque slope time. (unit: millisecond from 0 to
100% rated torque)
4. Set Target torque:6071hto the target torque. The unit is given one rated torque
in a thousand. (OD-6071h will be cleared to 0 if OD-6060h [Mode] changed. Servo-
Off or Quick-Stop is activated.)
5.7.3 Advanced Setting Procedures
Host could obtain the information of torque mode.
Read Torque demand value:6074
h
to obtain the output value of the torque limit
function. (unit: one rated torque in a thousand)
Read Torque rated current:6075
h
to obtain the rated current determined by the
motor and drive type. (unit: multiples of milliamp)
Read Torque actual value:6077
h
to obtain the instantaneous torque in servo
motor. (unit: one rated torque in a thousand)