Chapter 6 Control Modes of Operation ASDA-B2
6-10 Revision May, 2018
6.2.4 Low-pass Filter
Related parameters:
P1-08 PFLT
Smooth Constant of Position Command
(Low-pass Filter)
Address: 0110H
0111H
Operation
Interface:
Panel/Software Communication
Related Section:
Section 6.2.4
Default: 0
Control
Mode:
PT
Unit: 10 ms
Range: 0 ~ 1000
Data Size: 16-bit
Display
Format:
Decimal
Example: 11 = 110 msec
Settings: 0: Disabled
PFL
T
Target position
Position
Time (ms)