Chapter 10 Specifications ASDA-B2
10-14
Revision May, 2018
10.4 Overload Features
Definition of overload protection
The overload protection is to prevent the motor in overheat status.
Cause of overload
(1) When the motor operates over the rated torque, the operation time is too long.
(2) The inertia ratio is set too big and frequently accelerate / decelerate.
(3) Connection error between the power cable and encoder wiring.
(4) Servo gain setting error and cause resonance of the motor.
(5) The motor with brake operates without releasing the brake.
The graph of load and operating time
Low Inertia Series (ECMA C, CM Series)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-B2 Series and is the answer not in the manual?

Delta ASDA-B2 Series Specifications

General IconGeneral
Control ModePosition, Speed, Torque
Storage Temperature-20°C to 65°C
Position ControlYes
Speed ControlYes
Torque ControlYes
Output Power0.1 kW to 3.0 kW
Communication InterfaceRS-485, CANopen
Encoder FeedbackIncremental
ProtectionOvervoltage, Overcurrent, Overload, Overheat
Operating Temperature0°C to 55°C
Humidity20% to 90% RH (non-condensing)
Vibration Resistance5.9 m/s² (0.6G) at 10-55Hz