ASDA-B2 Chapter 7 Parameters
Revision May, 2018 7-29
P1-06 SFLT Analog Speed Command (Low-pass Filter)
Address: 010CH
010DH
Operation
Interface:
Panel/Software Communication
Related Section:
6.3.3
Default: 0
Control
Mode:
S
Unit: ms
Range: 0 ~ 1000 (0: Disabled)
Data Size: 16-bit
Format: Decimal
Settings: 0: Disabled
P1-07 TFLT
Analog Torque Command (Low-pass
Filter)
Address: 010EH
010FH
Operation
Interface:
Panel/Software Communication
Related Section:
6.4.3
Default: 0
Control
Mode:
T
Unit: ms
Range: 0 ~ 1000 (0: Disabled)
Data Size: 16-bit
Display
Format:
Decimal
Settings: 0: Disabled
P1-08 PFLT
Smooth Constant of Position Command
(Low-pass Filter)
Address: 0110H
0111H
Operation
Interface:
Panel/Software Communication
Related Section:
6.2.6
Default: 0
Control
Mode:
PT
Unit: 10ms
Range: 0 ~ 1000
Data Size: 16-bit
Format: Decimal
Settings: 0: Disabled