Chapter 7 Parameters ASDA-B2
7-30 Revision May, 2018
P1-09 SP1
Internal Speed Command 1 / Internal
Speed Limit 1
Address: 0112H
0113H
Operation
Interface:
Panel/Software Communication
Related Section:
6.3.1
Default: 1000
Control
Mode:
S, T
Unit: 0.1r/min
Range: -50000 ~ +50000
Data Size: 32-bit
Format: Decimal
Example 120 = 12 r/min
Settings: Internal Speed Command 1: The setting of the first internal speed
command.
Internal Speed Limit 1: The setting of the first internal speed limit.
P1-10 SP2
Internal Speed Command 2 / Internal
Speed Limit 2
Address: 0114H
0115H
Operation
Interface:
Panel/Software Communication
Related Section:
6.3.1
Default: 2000
Control
Mode:
S, T
Unit: 0.1r/min
Range: -50000 ~ +50000
Data Size: 32-bit
Format: Decimal
Example 120 = 12 r/min
Settings: Internal Speed Command 2The setting of the second internal
speed command.
Internal Speed Limit 2: The setting of the second internal speed
limit.