ASDA-B2 Chapter 8 Communications
Revision May, 2018 8-15
Description: After calculating CRC value, fill in the low word of CRC first in command
message, and then fill in the high word of CRC. For example, if the result of CRC algorithm
is 3794H, fill in 94H in low word and then 37H in high word.
Command Message
ADR 01H
CMD 03H
Starting data
address
01H (High)
01H (Low)
Number of data
(In Word)
00H (High)
02H (Low)
CRC Check Low
94H (Low)
CRC Check High
37H (High)