Installation and Operation Manual for Solar Power Inverter M70A EU V1.1 EN 2020-02-20
7 Installation
Safety precautions
7. Installation
Read chapter “5. Planning the installation”,
page 26 and this chapter in full before
you start installation.
7.1 Safety precautions
DANGER
Electric shock
Potentially fatal voltages are present in the
inverter during operation. When the inverter
is disconnected from all power sources, this
voltage remains in the inverter for up to 60
seconds.
You should therefore always carry out the fol-
lowing steps before working on the inverter:
1. Turn both DC isolating switches to the OFF
position.
2. Disconnect the inverter from all AC and DC
voltage sources and make sure that none
of the connections can be restored acciden-
tally.
3. Wait at least 60 seconds for the internal
capacitors to discharge.
DANGER
Electric shock
Potentially fatal voltages are present at the DC
connections of the inverter. When light falls on
the solar modules, they immediately start to
generate electricity. This also happens when
light does not fall directly on the solar modules.
Never disconnect the inverter from the solar
modules when it is under load.
Turn both DC isolating switches to the OFF
position.
Disconnect the connection to the grid so that
the inverter cannot feed energy into the grid.
Disconnect the inverter from all AC and DC
voltage sources. Make sure that none of the
connections can be restored accidentally.
Ensure that the DC cables cannot be
touched accidentally.
WARNING
Electric shock
If the doors of the inverter are open, the IP65
degree of protection is no longer guaranteed.
Only open the door when absolutely
necessary.
Do not open the door if water or dirt might
enter the inverter.
After work is completed, ensure that the
door is properly shut and tightened again.
Check that the doors are properly sealed.
WARNING
Heavy weight
The inverter is heavy.
The inverter must be lifted and carried by at
least two people.
ATTENTION
Water ingress.
All sealing caps removed during installation
should be stored for later use ( e.g. trans-
portation or storage).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta M70A and is the answer not in the manual?

Delta M70A Specifications

General IconGeneral
BrandDelta
ModelM70A
CategoryInverter
LanguageEnglish

Related product manuals