95
Installation and Operation Manual for Solar Power Inverter M70A EU V1.1 EN 2020-02-20
8 Commissioning
Commissioning with the commissioning software
8.3 Commissioning troubleshooting
Error message and cause of error Error correction
Error event
"Found more than expected inverters, please check your inverter quantity."
("More inverters found than expected. Please check the number of inverters.")
Cause of error
More inverters were found when scanning the RS485 ring than specied in the Inv num
text box.
1
2
► Check whether the entry in the
Inv num text box is correct.
Change the value if necessary.
► Check whether all inverters are
connected in the correct RS485
ring.
► To nish, click on the Scan
Inverters button (2).
Error event
"Only xx inverters found! Please check your 485 connection."
("Only xx inverters found. Please check the RS485 connection.")
Cause of error
Fewer inverters were found when scanning the RS485 ring than specied in the Inv num
text box.
1
2
► Check whether the entry in the
Inv num text box is correct (1).
Change the value if necessary.
► Check whether all inverters are
connected to the RS485 ring.
► To nish, click on the Scan
Inverters button (2).