Chapter 4 Parameters|VFD-VL
4-110
Settings 0.0 to 500.0%
10-12
ASR (Auto Speed Regulation) Control (I) of Zero Speed
Control
mode
VF VFPG SVC FOCPG FOCPM
Factory Setting: 0.100
Settings 0.000 to 10.000 sec
10-13
ASR (Auto Speed Regulation) control (P) 1
Control
mode
VF VFPG SVC FOCPG FOCPM
Factory Setting: 100.0
Settings 0.0 to 500.0%
10-14
ASR (Auto Speed Regulation) control (I) 1
Control
mode
VF VFPG SVC FOCPG FOCPM
Factory Setting: 0.100
Settings 0.000 to 10.000 sec
10-15
ASR (Auto Speed Regulation) control (P) 2
Control
mode
VF VFPG SVC FOCPG FOCPM
Factory Setting: 100.0
Settings 0.0 to 500.0%
10-16
ASR (Auto Speed Regulation) control (I) 2
Control
mode
VF VFPG SVC FOCPG FOCPM
Factory Setting: 0.100
Settings 0.000 to 10.000 sec
10-17
ASR 1/ASR2 Switch Frequency
Control
mode
VF VFPG SVC FOCPG FOCPM
Factory Setting: 7.00
Settings 0.00 o 400.00Hz
0.00: disable
ASR P determines Proportional control and associated gain (P). ASR I determines integral
control and associated gain (I).
When integral time is set to 0, it is disabled. Pr.10-17 defines the switch frequency for the
ASR1 (Pr.10-13, Pr.10-14) and ASR2 (Pr.10-15, Pr.10-16).
Call 1(800)985-6929 for Sales
deltaacdrives.com
sales@deltaacdrives.com
Call 1(800)985-6929 for Sales
deltaacdrives.com
sales@deltaacdrives.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta VFD-VL Series and is the answer not in the manual?

Delta VFD-VL Series Specifications

General IconGeneral
BrandDelta
ModelVFD-VL Series
CategoryDC Drives
LanguageEnglish

Related product manuals