Chapter 4 Parameters|VFD-VL
4-36
01-00
01-13,15,17,19
01-12,14,16,18
Frequenc
y
Time
M
ax. O utput
Frequency
Frequency
Setting
accel. time decel. time
Accel./Decel. Time
01-22
JOG Frequency
Control
mode
VF VFPG SVC FOCPG TQCPG FOCPM
Factory setting: 6.00
Settings 0.00~400.00Hz
Both external terminal JOG and key “JOG” on the keypad can be used. When the jog
command is ON, the AC motor drive will accelerate from 0Hz to jog frequency (Pr.01-22).
When the jog command is OFF, the AC motor drive will decelerate from Jog Frequency to zero.
The used Accel./Decel. time is set by the Jog Accel./Decel. time (Pr.01-20, Pr.01-21).
The JOG command can’t be executed when the AC motor drive is running. In the same way,
when the JOG command is executing, other operation commands are invalid except
forward/reverse commands and STOP key on the digital keypad.
Frequency
Time
01-22
JOG frequency
01-07
4th out put
frequency
setting
01-20
01-21
JOG acceleration time
JOG deceleration time
JOG accel./decel. time
01-23
Switch Frequency between 1st/4th Accel/decel
Control
mode
VF VFPG SVC FOCPG FOCPM
Factory setting: 0.00
Settings 0.00~400.00Hz
Call 1(800)985-6929 for Sales
deltaacdrives.com
sales@deltaacdrives.com
Call 1(800)985-6929 for Sales
deltaacdrives.com
sales@deltaacdrives.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta VFD-VL Series and is the answer not in the manual?

Delta VFD-VL Series Specifications

General IconGeneral
BrandDelta
ModelVFD-VL Series
CategoryDC Drives
LanguageEnglish

Related product manuals