ENGLISH
C'-S_t_e:..p_2_:_M_e_a_s_u_re_m_en_t
J
)
(Step
3 : Calculation
• Menu screen • •
Menu
screen •
o 0
)
(Step
4 : Check
•
Menu
screen •
o
)
After completing a measurement position, move the microphone to
the next position.
Measure at 6 positions: the main listening position
and
5 other
surrounding positions. Although it
is
allowable to measure less than 6
positions, it
is
recommended to measure 6 for best results.
ITSpeaker
Config.
Check
Distance
Check
Channel
Level
Check
Crossover
Freq.
Check
N
ext
~
When analysis
is
complete, check the analysis results for the following
four items.
CD
Make your selection using
£::,.
\l
and
press
ENTER.
• Presence and size of speaker
"Speaker Config. Check"
• Distance
of
speaker from listening position
"Distance Check"
• Speaker channel level
"Channel Level Check"
• Crossover Frequency
"Crossover
Freq.
Check"
@ Use
Do.
\l
to
change which speaker
is
displayed.
OTo
proceed
to
"Step
5:
Store"
Press
Do.
to select "Next
<OIl",
then press
<l.
Distance values that
are
greater than the actual distance of a speaker
may
be
accurate for speakers with built-in filters (subwoofers,
etc)
This
is
because these filters add electrical delay (distance) to the signal
that
is
compensated for
by
the Auto Setup process.
oTo switch
to
another analysis result item
Press
RETURN
.
This returns you to analysis results items,
so
repeat step
CD.
..
!---------_
__
_-
ITC
a
leu
I
ate
~
Ret
r y •
Cancel
~
• Analysis takes several minutes to complete.
• The time required for this analysis depends
on
the number of
speakers connected. The greater the number of speakers connected,
the longer analysis will take.
The values obtained from the measurements are automatically
analyzed and the attributes for each of the speakers
in
the listening
area
are determined.
CD
Press
Do.
to select "Calculate
<011",
then press
<l.
• Analysis begins.
-N·Ua
•
Do
not change the speaker connections or subwoofer volume,
or speaker locations after making measurements. If changes are
necessary, make the changes and use the Audyssey MultEO auto
setup once again for
an
updated
EO
solution.
•
For
instance, if the location or direction of a speaker
is
altered, the
Auto Setup should
be
performed again to ensure the correct
EO
solution for the
new
room configuration.
ITCancel.
.a.,
.•
"
I]'Next~
Calculate.
Cancel~
ITNext~
Calculate.
Ret
r y
~
Cancel.
CD
Press
Do.
to select
"Next
<OIl",
then press
<l.
• The measurement of the 2nd position starts.
® Move the microphone
to
the 3rd position and press
<l.
• The measurement
of
the 3rd position starts.
Q)
Perform @ repeatedly for the 4th, 5th, and 6th measurments.
• "All the measurements were finished." is displayed
on
the on-
screen display. When you have completed measurements
in
6
positions.
• If
you
want to stop after measuring just five or fewer positions,
press
\l
to select "Cancel
<011",
then press
<l.
I
27