EasyManuals Logo

Deprag AST6 User Manual

Deprag AST6
89 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #62 background imageLoading...
Page #62 background image
62
o Minimum differential moment
Lower limit of the differential end moment. The actual torque lower limit
results from the sum of the lower limit of the friction moment and the lower
limit of the differential moment.
Maximum differential moment
Upper limit of the differential end moment. The actual torque upper limit results from
the sum of the upper limit of the friction moment and the upper limit of the differential
moment.
Torque dwell time
A holding time can be defined to keep the moment for this time.
End value creation: Differential torque / total torque
Selectively the end torque can be displayed as difference between the total torque
and the torque of the previous level or as total torque in the end values.
Angle monitoring: yes / no
Monitoring of the angle with a window angle if the angle monitoring is switched on,
the following parameters are added:
Angle upper limit
Upper limit of the end angle. The value counts starting from the end of the friction
measurement.
Angle lower limit
Lower limit of the end angle The value counts starting from the end of the friction
measurement.

Table of Contents