OPERATOR’S MANUAL
Control Point
®
11001-1489-201702 Rev B
64 / KEYBOARD PROGRAMMING
Figure 41
Ground Speed Calibration, Single Speed Axle
7. On vehicles equipped with a 2-speed axle, the ground speed
calibration procedure must be performed in both the Hi-speed and
Lo-speed axle settings, refer to (Figure 42). The console automatically
detects when the axle ratio has been changed. To calibrate, simply
change the axle ratio and rerun.
8. Press the ESC key or any F key to leave the Calibration screen.
Figure 42
Ground Speed Calibration, Two Speed Axle
GROUND SPEED
SELECT A MENU ITEM
1 CALIBRATION
2 CONFIGURATION
GROUND SPEED CALIBRATION
ENTER THE GROUND
SPEED CONSTANT
OR
PRESS S TO START THE
CALIBRATION PROCEDURE
1 MILE
12000
Function Key F7
(GROUND SPEED)
• If known, manually enter constant
and press ENTER key.
TWO AXLE CALIBRATION
ENTER THE GROUND
SPEED CONSTANT
OR
PRESS S TO START THE
CALIBRATION PROCEDURE
1 MILE
12000
0