Diagnostics View system and event logs
IX14 User Guide
675
2. Use the show event command at the Admin CLIprompt:
> show event
Timestamp Type Category Message
---------------- ------- --------- --------------------------------------
-----
Nov 26 21:42:37 status stat
intf=eth1~type=ethernet~rx=11332435~tx=5038762
Nov 26 21:42:35 status system local_time=Thu, 08 Aug 2019 21:42:35
+0000~uptime=3 hours, 0 minutes, 48 seconds
...
>
3. (Optional) Use the show event number num command to limit the number of lines that are
displayed. For example, to limit the event list to the most recent ten lines:
> show event number 10
Timestamp Type Category Message
---------------- ------- --------- --------------------------------------
-----
Nov 26 21:42:37 status stat
intf=eth1~type=ethernet~rx=11332435~tx=5038762
Nov 26 21:42:35 status system local_time=Thu, 08 Aug 2019 21:42:35
+0000~uptime=3 hours, 0 minutes, 48 seconds
...
>
4. (Optional) Use the show event table value command to limit the number of lines that are
displayed. Allowed values are error, info, and status. For example, to limit the event list to
only info messages:
> show event table info
Timestamp Type Category Message
---------------- ------- --------- --------------------------------------
-----
Nov 26 22:01:26 info user
name=admin~service=cli~state=opened~remote=192.168.1.2
Nov 26 22:01:25 info user
name=admin~service=cli~state=closed~remote=192.168.1.2
...
>
5. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection