XBeePRO®900HP/XBeePRO®XSCRFModules
©2014DigiInternationalInc. 57
AT Command Options
Firmware Commands
Table5012. ATCommandOptions
AT
Command
Name and Description Parameter Range Default
CC
Command Character. Set or read the character to be used between guard times of the
AT Command Mode Sequence. The AT Command Mode Sequence causes the radio
modem to enter Command Mode (from Idle Mode).
0 - 0xFF 0x2B
CN Exit Command Mode. Explicitly exit the module from AT Command Mode. n/a n/a
CT
Command Mode Timeout. Set/Read the period of inactivity (no valid commands
received) after which the RF module automatically exits AT Command Mode and returns
to Idle Mode.
2-0x1770 0x64 (100d)
GT
Guard Times. Set required period of silence before and after the Command Sequence
Characters of the AT Command Mode Sequence (GT + CC + GT). The period of silence
is used to prevent inadvertent entrance into AT Command Mode.
0 to 0xFFFF
0x3E8
(1000d)
Table5013. FirmwareVersion/Information
AT
Command
Name and Description Parameter Range Default
VL
Version Long. Shows detailed version information including application build date and
time.
[read-only] n/a
VR Firmware Version. Read firmware version of the module.
0 - 0xFFFFFFFF [read-
only]
Firmware-set
HV Hardware Version. Read hardware version of the module. 0 - 0xFFFF [read-only] Factory-set
HS
Hardware Series. The module hardware series number. For example, if the module is
version S8B, this will return 0x801.
0-0xFFFF Factory-set
DD
Device Type Identifier. Stores a device type value. This value can be used to
differentiate multiple XBee-based products.
0-0xFFFFFFFF
[ read only ]
0xC0000
NP
Maximum RF Payload Bytes. This value returns the maximum number of RF payload
bytes that can be sent in a unicast transmission based on the current configurations.
0-0xFFFF
[read-only]
0x100
CK
Configuration CRC. The CRC of the current settings. The purpose of this command is
to allow the detection of an unexpected configuration change on a device. After a
firmware update, this command may return a different value.

Table of Contents

Other manuals for Digi XBEE-PRO S3B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Digi XBEE-PRO S3B and is the answer not in the manual?

Digi XBEE-PRO S3B Specifications

General IconGeneral
BrandDigi
ModelXBEE-PRO S3B
CategoryControl Unit
LanguageEnglish

Related product manuals