XBeePRO®900HP/XBeePRO®XSCRFModules
©2014DigiInternationalInc. 69
frame indicates that the transmission was successfully forwarded from the radio with serial
number 0x0013a2004052BBBB to the radio with serial number 0x0013a2004052CCCC.
Aggregate Addressing Update
Frame type: 0x8E
An Aggregate Addressing Update frame is output on an API-enabled node when an address update frame
(generated by the AG command being issued on a node in the network) causes the node to update its DH and
DL registers.
Example: In the above example a radio which had a destination address (DH/DL) of
0x0013A2004052AAAA updated its destination address to 0x0013A2004052BBBB.
Frame Fields Offset Example Description
A
P
I
P
a
c
k
e
t
Start Delimiter 00x7E
Length
MSB 1 0x00
Number of bytes between the length and the checksum
LSB 2 0x12
Frame-specific Data
Frame Type 30x8E
Format ID 40x00
Byte reserved to indicate format of additional packet
information which may be added in future firmware
revisions. In the current firmware revision, 0x00 is
returned in this field.
New Address
MSB 5 0x00
Address to which DH and DL are being set
60x13
70xA2
80x00
90x40
10 0x52
11 0xBB
LSB 12 0xBB
Old Address
13 0x00
Address to which DH and DL were previously set
14 0x13
15 0xA2
16 0x00
17 0x40
18 0x52
19 0xAA
20 0xAA
Checksum 21 0x2E 0xFF - the 8 bit sum of bytes from offset 3 to this byte.

Table of Contents

Other manuals for Digi XBEE-PRO S3B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Digi XBEE-PRO S3B and is the answer not in the manual?

Digi XBEE-PRO S3B Specifications

General IconGeneral
BrandDigi
ModelXBEE-PRO S3B
CategoryControl Unit
LanguageEnglish

Related product manuals