SELECTABLE OPERATING MODES
35
present).
- Once finished the programming of the set points, one should exit with the C key to return to weighing.
8.4 INPUT/OUTPUT ()
Simple display functioning mode with in / out weighing function: the indicator acquires two weight values
through the confirmation of the operator and calculates the difference, automatically printing the data (if
the presence of a printer has been configured).
The tare operations in this mode of operation are DISABLED.
8.4.1 PROCEDURE
With the MODE key of the 5-key indicator (or keys “F”+ “1” of the 17-key indicator), one acquires the first
weight, on the display is shown ““ accompanied by a prolonged beep.
By pressing again the MODE of the 5-key indicator (or keys “F”+ “2” of the 17-key indicator), one acquires
the second weight, and on the display is shown "" accompanied by a prolonged beep.
When the second weight is acquired, the data printout is commanded.
For the conditions of implementation of the weighing, refer to the section entitled “CONDITIONS FOR
PERFORMING THE WEIGH AND PRINTS”.
8.4.2 CANCELLATION WEIGH
It is possible to stop the weighing cycle by pressing the ENTER / PRINT key (in the 5-key indicator) or C (in
the 17-key indicator) after the acquisition of the first weight:
- The display shows the message “” accompanied by an audible signal.
- press ENTER/PRINT to confirm the cancellation of the first weight gained or another key to not confirm.
8.5 APPROVED TRANSMISSION OF WEIGHT TO PC WITH ALIBI MEMORY ()
The alibi memory allows to transmit the weight values in the computer for a further processing and / or
integration of data, and store them to then be recalled from the “PID” or “PIDD” PC serial command(see
“FORMAT OF THE SERIAL COMMANDS” paragraph on technical manual) or directly on the display of the
indicator to be checked.
The data stored at each weigh / weight transmission is:
- Gross weight
- Tare
- Unit of measure
- Number of scale (always 1)
- Alibi rewriting ID
8.5.1 PROCESS FOR STORAGE
The storage of a weigh takes:
- following the reception of a command via serial.