CT100 inverter Function parameters
78
Function
code
Name
Detailed instruction of
parameters
Min. unit
Default
value
Modify
No.
F08.19
Frequency at
current fault
0.01Hz
F08.20
Current at
current fault
0.1A
F08.21
Bus voltage at
current fault
0.1V
F08.22
Input terminal
status at current
fault
1
F08.23
Output terminal
status at current
fault
1
F09 Group PID function
F09.00
PID reference
channel
0: digital reference (F09.01)
1: AI1
2: AI2
3: HDI
4: multi-step speed
5: 485 communication
1
0
F09.01
PID keypad
reference
0.0%100.0%
0.1%
0.0%
F09.02
PID feedback
channel
0: AI1
1: AI2
2: AI1+AI2
3: HDI
4: 485 communication
1
0
F09.03
PID direction
0: positive
1: negative
1
0