CT100 inverter Function parameters
79
Function
code
Name
Detailed instruction of
parameters
Min. unit
Default
value
Modify
No.
F09.04
PID output
upper limit
(reserved)
-100.0%100.0%
0.1%
100.0%
F09.05
PID output
lower limit
(reserved)
-100.0%100.0%
0.1%
0.0%
F09.06
Proportional
gain P
0.00100.00
0.01
0.10
F09.07
Integral time I
0.0110.00s
0.01s
0.10s
F09.08
Differential time
D
0.0010.00s
0.01s
0.00s
F09.09
Sampling cycle
T
0.00100.00s
0.01s
0.10s
F09.10
PID control
deviation limit
0.0100.0%
0.1%
0.0%
F09.11
Feedback loss
detection value
0.0100.0%
0.1%
0.0%
F09.12
Feedback loss
detection time
0.03000.0s
0.1s
1.0s
F10 Group Wobble, step length and count value
F10.00
Jump frequency
1
0.00 F00.06 (Max.
frequency)
0.01Hz
0.00Hz
F10.01
Jump frequency
2
0.00 F00.06 (Max.
frequency)
0.01Hz
0.00Hz
F10.02
Jump frequency
amplitude
0.00 F00.06 (Max.
frequency)
0.01Hz
0.00Hz
F10.03
Wobble
amplitude
0.0 100.0% (relative to the
set frequency)
0.1%
0.0%

Table of Contents