5.2.4 Every 8 operating hours
Check for the good lubricating oil conditions in
the oil chamber (see the section Lubricating oil
checking).
See the section Lubricating oil
changing/refilling.
Tab. 8
5.2.5 Every 50 operating hours
Check the tightening of the bolts and of any
other threaded component of the pump.
Tight correctly (see Bolts
tightening torque in this manual)
Check for the good conditions of the agitator.
See the section Agitator kit in
this manual
Tab. 9
5.2.6 Every 150 operating hours
Check the clearence between impeller and
lower wear plate (see the section Impeller
clearence checking).
See the section Impeller
clearence adjusting.