EL7.5 - EL12.5 (S - SS) User manual - ENG 40/70
5.3.3 Impeller clearence checking
This check must be performed every 150 operating hours in order to prevent a
performance loss of the pump.
For the impeller clearence checking, proceed as follows (see Fig. 21):
- remove the strainer (see Strainer section);
- using a feeler, check that the space between the lower wear plate [7] and the
impeller [1] doesn’t exceed 1 mm;
- if the measured clearence is more than 1 mm, proceed immediately with the
clearence adjusting (see Impeller clearence adjusting section).
Fig. 21
Reassemble all the components in reverse order to restore the pump at the initial
conditions. Before reassembling, check the good conditions of any bolt and eventually
replace the damaged ones.